11 points that must be paid attention to when installing the transformer

Release date:2018-12-20 17:13:54

11 points that must be paid attention to when installing the transformer


1. Reasonably choose the installation location of the distribution transformer:
The installation of the distribution transformer should meet the requirements of the user's voltage, and try to avoid installing the distribution transformer in the barren hills, which is vulnerable to lightning strikes and away from the residential area. This is not convenient for the maintenance personnel to maintain regularly, and it is not convenient for the staff to manage. .
2. Reasonably choose the capacity of the distribution transformer
It is also very important to choose the capacity of the distribution transformer reasonably, which can not cause the load of the distribution transformer to burn out, nor can it cause the waste of the big horse-drawn trolley type. According to the user load situation, the capacity should be counted and the distribution transformer capacity should be reasonably selected.
3. Strengthen the measurement of power load
During the peak period of power load, the load of each distribution transformer should be strengthened. If necessary, increase the number of measurements. The distribution transformer that does not meet the three-phase current should be adjusted in time to prevent the neutral current from being too large and easy to blow the lead. Causes the user equipment to burn out.
4. Avoid installing a low-voltage metering box on the distribution transformer.
The low-voltage metering box installed on the distribution transformer station area of ??the remote mountainous area should be gradually removed, and changed to indoor installation as much as possible.
5, reasonable allocation of distribution transformer high and low temperature melting point electrical melting
The melt distribution of the high and low voltage fuses of the distribution transformer is unreasonable, which may cause serious overload of the distribution transformer and burn out the distribution transformer. The high and low pressure melt configuration shall be followed by: a fuse body with a capacity of 100 kV·A or less and a fuse body with a rated current of 2.0 to 3.0 times; and a transformer with a capacity of 100 kV·A or more with a melt of 1.5 to 2.0 times the rated current; The low-voltage side fuse should be configured slightly larger than the rated current.
6, should not adjust the tap changer privately
Due to the difference in power load between winter and summer, the voltage level is slightly different. In order to meet the voltage demand, some rural electricians randomly adjust the tap changer without performing related tests, causing the tap changer to be out of position, causing phase-to-phase short-circuit and burnout. Electric transformer.
7, distribution transformer high and low installed insulation cover
In order to prevent natural disasters and external damage, if necessary, install high and low voltage insulation covers for the narrow roads and forest protection areas to prevent the low voltage short circuit from burning the transformer on the distribution transformer.
8. Arrest arresters should be installed on the high and low voltage sides of the distribution transformer.
Lightning arresters should be installed on the distribution transformers in the multi-mine area. If the quality of the arrester is unqualified or the fault is not replaced in time, it is easy to be attacked by lightning. During the thunderstorm season, the arrester should be sent to the repair department for testing and timely installation. It is forbidden to use unqualified products.
9. Regularly measure the grounding resistance of the distribution transformer
After long-term operation of the distribution transformer (especially the grounding lead is replaced by aluminum wire), severe oxidation occurs, the grounding resistance increases, and the buried grounding body is rusted and broken, causing the neutral point potential to shift. When lightning strikes or overvoltages , easy to cause an accident. According to the regulations, the grounding device should meet: the grounding resistance of the distribution transformer below 100kV·A is not more than 10Ω, and the grounding resistance of the distribution transformer above 100kV·A is not more than 4Ω.
10. Strengthen daily management
Regularly patrol the line, cut down trees, prevent the branches from hitting the wires and causing a low voltage short circuit to burn the distribution transformer. The lack of daily management of the distribution transformer by the staff makes the transformer run out of oil for a long time. The end of the respirator is installed or the silica gel is not replaced in time, so that the distribution transformer is flooded and easily caused accidents. There are quality problems in the distribution transformer itself. Because the distribution transformer is installed far away, some construction personnel put the untested distribution transformer into operation, temporarily use electricity, and burn out the transformer.
11, regularly check the distribution transformer low voltage lead
It is strictly forbidden to use the wire itself to make the wire nose directly on the low-voltage pile head of the distribution transformer. It is necessary to regularly check and strengthen the joint between the lead wire and the distribution transformer pile head to prevent the low-voltage pile head of the distribution transformer from being burnt due to loosening.

Article keywords:
Previous article:No last one Next article:What are the functional characteristics ...
QR code
主站蜘蛛池模板: 一级黄色片免费的 | 精品一区二区三区在线观看视频 | 日本a一级毛片免费观看 | 欧美成人性毛片免费版 | 一级女性全黄生活片免费 | 男女爱爱福利 | 久久午夜免费鲁丝片 | 日本免费一区二区在线观看 | 黄的日本免费大片 | 国产成人a v在线影院 | 亚洲不卡视频在线观看 | 在线播放免费一级毛片欧美 | 一男一女一级毛片 | 国内精品小视频福利网址 | 一级毛片毛片毛毛片毛片 | 91人成亚洲高清在线观看 | 最近免费字幕中文大全在线观看 | 日韩国产精品视频 | 久久久免费精品 | 欧美精品国产一区二区三区 | 午夜影视免费完整高清在线观看网站 | 国产一区在线观看视频 | 外女思春台湾三级 | 欧美一区二区三区在线观看不卡 | 在线观看精品国语偷拍 | 日本韩国欧美在线 | 一级成人a毛片免费播放 | 成年人免费大片 | 一级做a毛片免费视频 | 国产成社区在线视频观看 | 日韩福利片午夜在线观看资源 | 欧美一区不卡二区不卡三区 | 国产香蕉在线视频一级毛片 | 中文在线观看永久免费 | 特级黄色毛片 | 国产精品久久久久久福利69堂 | 亚洲国产一级a毛片 | 国产成人精品视频播放 | 国产视频资源 | 国产精品夜色视频一级区 | 日韩精品欧美成人 |